NDT X RAY Pipeline Crawler
X-ray pipeline crawler, X-ray nondestructive testing instrument. Suitable for conveying oil, natural gas or other movable material pipeline weld quality inspection.
Two positioning methods are used: magnetic medium positioning or microwave positioning.
Accurate positioning, reliable operation, quick stopping and braking; High work efficiency, one imaging, passing rate of 100%; Reasonable structure, strong shockproof, large driving force, flexible rotation, microcomputer automatic control, strong anti-interference ability; Own power supply, maintenance-free, pollution-free, safe and reliable, long practical life, simple operation, health and environmental protection.
Key Features:
1. Advanced control technologies
Industrial-grade microcomputer control is used for more accurate and reliable operation.
2. New high-efficiency battery
Due to the use of a large international brand of power lithium batteries, making the crawler smaller in size, lighter in weight and more reliable in performance.
3. It adopts dual positioning of magnetic control and video to meet users' requirements of higher positioning accuracy.
| SF-08-D219 | SF-08-D300 | |
| Applicable pipe diameter | Φ200~400mm | Φ290~1400mm |
| Turning radius | ≥5D | ≥5D |
| Positioning accuracy | ±5mm | ±5mm |
| Maximum gradeability | 20° | 20° |
| Crawling speed | 23m/min at high speed, 11m/min at low speed | 23m/min at high speed, 11m/min at low speed |
| Crawling distance | ≥6km | ≥6km |
| Maximum radiographic wall thickness | 8~20mm (sbject to the generator allocated) | 20~40mm (sbject to the generator allocated) |
| Total exposure time | ≥100min | ≥100min |
| Total length of crawler | 1350mm | 1250mm |
| Total weight of crawler | 33kg | 43kg |
| Voltage of power supply | DC120V | DC120V |
| Battery capacity | 15AH | 20AH |
| Working temperature | -15~55 ºC | -15~55 ºC |
| Working current | 3-5mA | 3-5mA |
| Battery life | Three years | Three years |
| Warranty period | One year | One year |
System Components
The crawler is mainly composed of several parts, such as the body, drive and drive mechanism, magnetic control controller, microwave controller, battery pack, X-ray generator, signal receiving device, charger, etc.
Body: the carrier of the crawler components
Drive and transmission mechanism: It consists of motor and reducer
Controller: to control the crawler to complete various functions
Battery pack: to provide power for the crawler to work
X-ray generator: X-ray generating device for exposure of pipeline welds
Signal receiving device: to receive external pipeline command source and microwave signal
Charger: to charge the battery pack and the magnetic-controlled and microwave control box