Fiber laser Cutting Machine L3
| Models | L3-30 | L3-40 | L3-4020 | L3-6020 |
| XY working range (mm) | 3048 x 1524 | 4064 x 1524 | 4064 x 2032 | 6096 x 2032 |
| Z axis stroke (mm) | 100 | 100 | 100 | 100 |
| Maximum XY speed (m/min) | 156 | 156 | 156 | 156 |
| Precision1 | ||||
| Position accuracy Pa | 0.08 | 0.08 | 0.08 | 0.08 |
| Average position range Ps | 0.03 | 0.03 | 0.03 | 0.03 |
| Fiber sources | 2000W | 3000W | 4000W | 6000W | 8000WE5 | 8000W | 10000W |
| Cutting capacity (maximum thickness in mm)2 | |||||||
| Steel | 15 | 20 | 20 | 25 | 25 | 25 | 25 |
| Stainless steel | 10 | 12 | 15 | 20 | 25 | 25 | 30 |
| Aluminum | 8 | 10 | 15 | 20 | 25 | 25 | 30 |
| Copper | 5 | 8 | 8 | 8 | 10 | 10 | 10 |
| Brass | 5 | 6 | 8 | 8 | 10 | 10 | 10 |
| Minimum thickness (mm) | 0.5 | ||||||
| Consumption (in kW) | |||||||
| Maximum absorbed power (in kW)3 | 16 | 18 | 21 | 28 | 28 | 34 | 42 |
| Average absorbed power (in kW)4 | 11 | 12 | 13 | 16 | 16 | 20 | 24 |
1 Measurement calculated according to VDI3441 on maximum axis lengths.
2 Cutting quality on limit thicknesses may depend on geometries required, material quality and system operating conditions. At limit values, burrs may be present on the lower edge of the cut. These values are for the Salvagnini reference materials.
3 Maximum absorbed power calculated on a system with standard configuration when cutting 3 reference sheets of mild steel with a thickness of 0.8-6 mm.
4 Average absorbed power calculated on a system with standard configuration when cutting 3 reference sheets of mild steel with a thickness of 0.8-6 mm.
5 High efficiency version.