Add product
Product / Equipment

CEMS-2000 Industrial Emissions Monitoring System

(Equipment / Material)
Model Number: CEMS-2000
Condition: New
Location or Storage Country: Russia
Service Engineering Support: Yes
Warranty: No
Price: Call for price
Description:
CEMS-2000 Automatic Continuous Industrial Emissions Monitoring System (Automatic Measuring System)
Overview:

The CEMS-2000 industrial emissions monitoring system is designed to implement the requirements of the Federal Law of July 21, 2014 No. 219FZ . The measurement methods used in the CEMS-2000 system are recommended by ITS 22.1-2016 General principles of industrial environmental control and its metrological support (BAT) .

The CEMS-2000 industrial emissions monitoring system allows continuous monitoring of the content of sulfur dioxide (SO 2 ), nitrogen oxides (NO, NO 2 , NO x in terms of NO 2 ), carbon monoxide and carbon dioxide (CO, CO) in gas emissions 2 ), oxygen (O 2 ), particulate matter (dust), optionally hydrogen fluoride and chloride (HF, HCl), hydrogen sulfide (H 2 S), ammonia (NH 3 ), hydrocarbons, and also control the physical parameters of emissions (temperature, pressure, flow rate and humidity of the exhaust gases).

In the gas analytical part of the CEMS-2000 industrial emissions monitoring system, optical measurement methods are used, due to which the system has high measurement accuracy and requires virtually no maintenance:

  • differential optical absorption spectroscopy (DOAS) in the UV-Vis range;
  • non-dispersive infrared method (NDIR);
  • semiconductor laser absorption spectroscopy ( TDLAS ).

To monitor the content of solid particles (dust), the optical method is also used, based on the detection of visible radiation scattered by dust particles.

The system is built on the principle of measuring hot and wet samples (heated sampling probe, sample transport line and measuring cell), which corresponds to ITS 22.1-2016.

The complex includes specialized software CEMS-2000.

Purpose and features of software:

- configuration of the mode of operation of the system;

- system management;

- making report;

- display of data on current concentrations (mg / m 3 );

- display of values reduced to normal conditions;

- display of information on mass emissions (g / s);

- display of information about the flow parameters;

- display of all data in digital and graphic form in real time;

- data transmission in digital and analog form;

- Russian-language interface.

The CEMS-2000 software has a conclusion of NII Atmosfera JSC on the compliance of the algorithm for calculating mass emissions with current regulatory documents.

CEMS-2000 Industrial Emission Monitoring System Architecture

CEMS-2000 Industrial Emissions Monitoring System Installation Diagram

METROLOGICAL CHARACTERISTICS

Component

Measuring range

volume fraction *

Permissible limits

basic error

mn -1 (ppm)

% (vol)

reduced, γ,%

relative, δ,%

SO 2

0 - 100

-

± 8

-

St. 100 - 1000

-

-

± 8

0 - 1000

-

± 6

-

St. 1000 - 5000

-

-

± 6

NO

 

0 - 100

-

± 8

-

St. 100 - 1000

-

-

± 8

0 - 1000

-

± 6

-

St. 1000 - 3000

-

-

± 6

NO 2

0 - 100

-

± 8

-

St. 100 - 1000

-

-

± 8

The sum of nitrogen oxides (NO x ) in terms of NO 2

 

0 - 100

-

± 8

-

St. 100 - 1000

-

-

± 8

0 - 1000

-

± 6

-

St. 1000 - 3000

-

-

± 6

CO

 

0 - 100

-

± 8

-

St. 100 - 1000

-

-

± 8

0 - 1000

-

± 6

-

St. 1000 - 5000

-

-

± 6

-

0 - 0.5

± 5

-

-

St. 0.5 - 1.2

-

± 5

CO 2

-

0 - 5

± 3

-

-

St. 5 - 20

-

± 3

About 2

-

0 - 5

± 5

-

-

St. 5 - 30

-

± 5

H 2 O

-

0-10

± 10

-

-

St. 10 - 40

-

± 10

Definable

parameter

Units

measurements

Range

measurements

Permissible limits

absolute error,%

Temperature

gas sample

about C

from 0 to 400

± 2.0

Pressure

kPa

from - 10 to 10

± 0.1

Flow rate

m / s

4 - 35 (pitot)

0.1 - 40 (ultrasound)

± 1.0

± 3.0

Metrological and technical characteristics of analyzers of hydrogen fluoride and chloride (HF, HCl), hydrogen sulfide (H 2 S), ammonia (NH 3 ) and other components:

Gas analyzer LGA-4100 Gas analyzer LGA-4500

SPECIFICATIONS

Parameter Name

Value

Measurement methods

Optical, hot and wet samples

Filtration system

Multistage
Probe cleaning system Automatic and manual
Calibration system Automatic and manual
Units (programmable) ppm, mg / m 3 ,% vol, g / s
Digital interfaces RS-232, RS-485, USB, LAN, RS-232 / GPRS
Analog outputs

(1 per component) 0-1 V, 0-10 V, 0-20 mA, 4-20 mA

Output Scales

programmable

Sample Consumption

1.5 l / min.

Power supply

230 V 50 Hz

Complex power consumption

1 - 4.8 kW (depending on configuration)

Alarm and warning monitoring

constant; detection and indication of malfunctions; out of range

The CEMS-2000 industrial emissions monitoring system has been included in the State Register of the SI of the Russian Federation under No. 71638-18

LLC "GROUP AI-SI"

Locations: Russia Moscow
Main Products/Services: Turnkey delivery and maintenance of industrial emission control systems and environmental monitoring systems
Registration: Russia Moscow