UPS ONTEK Power 10, RT 10Kva/10Kw 3P/3P (PF=1) 3U
(设备/材料)
概观:
Model: PW10/33 | |
---|---|
Entrance | |
Exit | |
Efficiency | |
Charger | |
Physical parameters | |
Control | |
Correspondences | |
Phase | 3 phase input / 3 phase output |
Power | 10000VA/10000W |
Possibility of parallel operation | 10 |
Nominal voltage | 3 x 380V/400V/415V (3Ph+N+PE) |
Voltage range | 190-520V (3-phase) at 50% load; 305-478V (3-phase) at 100% load |
Frequency range | 40-70 Hz |
Power factor | ≥ 0.99 at 100% load |
Harmonic distortion (THDi) | < 4% at full linear load |
Output voltage | 380V/400V/415V (3Ph+N) |
Voltage regulation (battery mode) | ± 1% |
Frequency range (synchronized range) | 46-54 Hz or 56-64 Hz |
Frequency range (battery mode) | 50Hz ±0.1Hz or 60Hz ±0.1Hz |
Crest factor | 3:1 (max) |
Harmonic distortion | ≦ 2% THD (linear load); ≦ 3% THD (non-linear load) |
Time to switch to batteries | Zero |
Bypass transition time | Zero |
Waveform in battery mode | Pure sine wave |
Online overload | 100-110% for 30 min, 110-130% for 5 min, 130-150% for 10 sec; >150% - 200 ms |
Intelligent online congestion management | Overload tolerance is linearly dependent on the overload degree. After the overload time has expired, switching to bypass. The options "Disabled" or "Disable bypass" are possible, in this case, the load is disconnected. |
Overload in battery mode | 100-110% for 3 min, 110-130% for 30 sec, 130-150% for 10 sec; >150% - 200 ms |
Intelligent overload management in battery mode | If the bypass is in working condition, switching to bypass occurs, otherwise, the load is disconnected. |
From the network | 94% |
ECO mode | 97% |
Battery mode at full load | 93% |
Battery mode, peak | 93.5% |
Batteries | ± 12V / 9Ah |
Number of batteries | 16-20 pcs (adjustable) x 2 |
Nominal voltage | +/-192V (12V x 32 pcs) |
Maximum voltage | +/- 240V (12V x 40 pcs) |
Minimum voltage | +/-192V (12V x 32 pcs) |
Charging voltage | ± 218V |
Standard charging time | 9 hours to 90% capacity |
Charging current | 4A |
Dimensions (W×H×D) mm | 418×129×678 (3U) |
Net weight (kg) | 20.5 |
LCD screen | UPS status, load level, battery level, input/output voltage, discharge timer, errors and warnings |
terms of Use | Humidity 0-95% at 0-40°C (non-condensing) |
Noise level | Less than 55dB at 1 meter |
Smart RS-232/USB | Support Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
SNMP (optional) | Power management using SNMP manager and web browser |
Warranty period | 3 years |