添加产品
Product / Equipment

VVG cable

(设备/材料)
型号编号: ВВГ
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: Yes
价钱: 要求价格
概观:

Decoding of VVG cable:
B - insulation of cores made of polyvinyl chloride plastic
B - sheath made of low-flammability polyvinyl chloride plastic
G - absence of protective coverings

Elements of the VVG cable design:
The conductive core is copper, single-wire or multi-wire, round or sector-shaped, class 1 or 2 according to GOST 22483.
Insulation – made of polyvinyl chloride plastic. Insulated cores of multi-core cables have a distinctive color. Insulation of neutral cores (N) is blue. Insulation of ground cores (PE) is two-colored (green and yellow).
Twisting – insulated cores of multi-core cables are twisted into a core.
Conductive screen (for cables with a voltage of 6 kV) - applied with a winding of conductive cable paper tape.
Metal screen (for cables with a voltage of 6 kV) - made of copper tapes or copper foil.
The shell is made of polyvinyl chloride plastic.

Technical parameters of VVG cable:
Type of climatic performance of cables UHL and T, placement categories 1 and 5 according to GOST 15150.
Operating temperature range from -50°C to 50°C.
Relative air humidity at temperatures up to 35°C up to 98%.
Laying and installation of cables without preliminary heating is carried out at a temperature not lower than -15°C.
Permissible bending radius of cables during installation:
- single-core - not less than 10 outer diameters;
- multi-core - not less than 7.5 outer diameters.
The permissible forces when pulling cables along the installation route must not exceed 50 N/mm².
The cables do not spread combustion when laid individually (IEC 60332-1 standards).
Fire hazard class according to GOST 31565-2012: O1.8.2.5.4.
The long-term permissible heating temperature of cable cores during operation is no more than 70°C.
The maximum permissible heating temperature for wires with a cross-section of up to 240 mm² at short-circuit currents is no more than 160°C.
The maximum permissible heating temperature of wires with a cross-section of 300 mm² at short-circuit currents is no more than 140°C.
The duration of a short circuit should not exceed - 5 s.
The permissible heating temperature of cable cores in overload mode is no more than 90°C.
The maximum heating temperature of the wires under conditions of non-ignition during a short circuit is no more than 350°C.
The construction length of cables is set when ordering.
Service life - 30 years from the date of manufacture of cables.
The warranty period is 5 years from the date of commissioning of the cables, but not later than 6 months from the date of manufacture.
Shelf life:
- in open areas - no more than 2 years;
- under a canopy - no more than 5 years;
- indoors - no more than 10 years.

JSC "Marposadkabel"

地点: 429570, Chuvashia Republic, Mariinsky Posad, Nikolaeva St., 93
主要产品/服务: Cable