添加产品
Product / Equipment

KPPBP-125 - Cables for Submersible Electric pumps

(设备/材料)
型号编号: КПпБП-125
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: Yes
价钱: 要求价格
描述:
Cable for submersible electric pump units, flat, with copper conductors, with heat-resistant polypropylene insulation, armoured with galvanised steel tape, with a long-term permissible heating temperature of the conductors of 125 °C. Manufactured according to TU 16.K73.076-2006, meets the requirements of GOST R 51777-2001. Designed to supply electric energy to submersible electric motors of oil production units, water lifting and pumping liquid from pits, tanks and reservoirs, designed for a rated alternating voltage of 3.3 kV, 4.0 kV and 5.0 kV with a frequency of 50 Hz. Used for operation in well fluid containing oil, as well as water and gas with the following indicators: - hydrogen index of associated water, pH - 6.0-8.5; - hydrogen sulfide concentration, % (g / l): no more than 0.001 (0.01); - hydrostatic pressure, MPa, no more than – 25; - gas factor, m3/m3, no more than – 500. OKP CODE: 35 4200
概观:

Climate version UHL, placement categories 1 and 5 according to GOST 15150.
The cables can withstand crushing loads of at least 158 kN.
Insulated cores are longitudinally sealed with a liquid pressure difference of 0.02 MPa per 1 m of length.
Electrical insulation resistance of the main conductors, recalculated for a length of 1 km and a temperature of 20 °C: not less than 2500 MOhm.
The cables can withstand a DC voltage test of 18 kV (nominal cable voltage 3.3 kV), 20 kV (nominal cable voltage 4.0 kV and 5.0 kV) for at least 5 minutes, while the insulation leakage current recalculated for a length of 1 km and a temperature of 20 °C does not exceed 1x10-5 A.
Cable bending radius: not less than 380 mm.
Lowering, lifting and rewinding operations with cable must be carried out at an air temperature of not lower than -30 °C.
Cable rewinding and lowering and lifting operations with it are permitted at an air temperature of no lower than -40 °C under conditions of artificial heating of the cable, ensuring a temperature of no lower than -30 °C.
The cables are resistant to temperature changes from -60 °C to the long-term permissible heating temperature of the cores.
The lowering of the cable into the well and its lifting out of it must be done smoothly at a speed of no more than 0.25 m/s.
When passing sections of the well pipe column with a curvature of more than 1.5° per 10 m and places where the column transitions to a smaller pipe diameter, the descent and ascent speeds should not be more than 0.1 m/s.
When fastening the cable to the pump-compressor pipes and screwing the pipes together, twisting the cable around the pipes and twisting the flat cable relative to its own axis is not allowed.
The cable is supplied in construction lengths agreed upon with the Customer.
Warranty period for cables: 18 months from the date of commissioning, but not more than 24 months from the date of shipment to the Consumer.

JSC "EKZ"

地点: Yekaterinburg, Melnikova st., 2
主要产品/服务: Cable