By accessing and utilizing our servers, services, websites, or any associated content/postings, you agree (individually and on behalf of a business if applicable) to our Terms of Use (below), which we may update anytime at our discretion. If you do not agree to the Terms of Use (“Terms”), then you are not authorized to use any of our materials for either posting or viewing/search purposes.

More info

4 + 5 =
解答这道简单的数学问题并输入结果。 例如。 对于1 + 3,请输入4。
这个问题被要求找出是否你是一个人或自动发送同样的消息到多个新闻组邮件列表。
添加产品
Product / Equipment

DPT cable

(设备/材料)
型号编号: ДПТ
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: Yes
价钱: 要求价格
概观:
Permissible tensile load (PTL), kN 4
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 115.6 126.4 137.8 148.4
Bending radius, mm 183 192 201 210
Permissible tensile load (PTL), kN 6
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 115.6 126.4 137.8 148.4
Bending radius, mm 183 192 201 210
Permissible tensile load (PTL), kN 7
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 116.6 126.4 137.8 148.4
Bending radius, mm 183 192 201 210
Permissible tensile load (PTL), kN 8
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.3 12.8 13.4 14.0
Cable weight, kg/km 118.0 127.0 137.8 148.9
Bending radius, mm 185 192 201 210
Permissible tensile load (PTL), kN 10
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.4 12.9 13.4 14.1
Cable weight, kg/km 120.6 129.8 138.8 152.2
Bending radius, mm 186 194 201 212
Permissible tensile load (PTL), kN 12
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.5 13.0 13.5 14.2
Cable weight, kg/km 123.4 132.2 141.3 155.0
Bending radius, mm 188 195 203 213
Permissible tensile load (PTL), kN 15
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 12.6 13.1 13.6 14.3
Cable weight, kg/km 127.8 136.1 144.8 159.6
Bending radius, mm 189 197 204 215
Permissible tensile load (PTL), kN 20
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 13.2 13.6 13.8 14.9
Cable weight, kg/km 136.2 143.8 151.1 168.4
Bending radius, mm 198 204 207 224
Permissible tensile load (PTL), kN 25
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 13.5 13.9 14.3 15.2
Cable weight, kg/km 143.3 150.9 158.8 176.5
Bending radius, mm 203 209 215 228
Permissible tensile load (PTL), kN 30
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 13.8 14.2 14.6 15.6
Cable weight, kg/km 150.4 157.5 165.0 184.6
Bending radius, mm 207 213 219 234
Permissible tensile load (PTL), kN 35
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 14.9 15.3 15.7 16.5
Cable weight, kg/km 171.1 180.5 189.9 207.2
Bending radius, mm 224 230 236 248
Permissible tensile load (PTL), kN 40
Permissible crushing load, kN/cm 0.3
Number of optical fibers in a cable, up to 48 (6x8) 72 (6x12) 96 (6x16) 144 (6x24)
Cable diameter, mm 15.2 15.6 16.0 16.8
Cable weight, kg/km 178.4 187.7 197,0 215.6
Bending radius, mm 228 234 240 252

LLC "Inkab"

地点: Perm region, Perm district, village Nestyukovo, Pridorozhnaya street, 2
主要产品/服务: Cable