名字和姓氏
有效的电子邮件地址。 该地址将用于系统电子邮件和通知。
使用条款
Show terms

By accessing and utilizing our servers, services, websites, or any associated content/postings, you agree (individually and on behalf of a business if applicable) to our Terms of Use (below), which we may update anytime at our discretion. If you do not agree to the Terms of Use (“Terms”), then you are not authorized to use any of our materials for either posting or viewing/search purposes.

More info

14 + 6 =
解答这道简单的数学问题并输入结果。 例如。 对于1 + 3,请输入4。
这个问题被要求找出是否你是一个人或自动发送同样的消息到多个新闻组邮件列表。
添加产品
Product / Equipment

Installation wires KUIN-Pu According to TU 3551-023-76960731-2012

(设备/材料)
型号编号: КУИН-Пу
状态: New
位置或存放国家: Russia
服务工程支持: Yes
保证: Yes
价钱: 要求价格
描述:
KUIN-Pu wires fully comply with the new GOST R 53768-2010 "Wires and cables for electrical installations with rated voltage up to 450/750V inclusive. OTU" - which on 01.01.2011 replaced GOST 6323-79, in connection with which wires of the PV1, PV2, PV3, PV4, PPV, APV and APPV brands according to GOST 6323-79 can no longer be used on the territory of the Russian Federation.
概观:
  • The cores of the high-flexibility wires are copper multi-wire class 5 according to GOST 22483, the cores of normal flexibility are class 1 or 2
  • Wide temperature range of application:
    • from -60° to +70°C with the designation "ХЛ"
    • from -60° to +125°C with material "T"
    • from -50° to +200°C with material "T-T"
    • from -50° to +70°C for other types
  • Minimum installation temperature, not lower than:
    • -30°С with the designation "ХЛ" or material "T"
    • -15°С for other types of wires and cables
  • Version B, placement category 1-5 (according to GOST 15150). It is possible to use wires in all macroclimatic regions, including the tropics
  • "UV" - resistant to solar radiation
  • "B" - protection against moisture spreading under the shell
  • "M" - oil and petrol resistant casing
  • Wires can have:
    • copper wire or alumoflex screen
    • armor made of galvanized steel wires
  • The resistance of the conductors to direct current complies with GOST 22483
  • Nominal voltage
    • for wires: ∼450/750V to 400Hz or -1000V
  • Electrical insulation resistance at temperature t = +20°C not less than 5 MOhm•km
  • Voltage test according to GOST 23286-78:
    • insulated cores for passage according to category EI-2
    • wires ∼2500V 50Hz for 5 min according to EI-1
  • Fire-resistant wires remain operational in fire conditions for at least 90 minutes (PO4 according to GOST R 53315-2009)
  • Low toxicity wires "LTx" - the best fire safety indicator

JSC "Kubankabel"

地点: Russian Federation, 352903, Krasnodar Region, Armavir, Urupskaya St., 1a
主要产品/服务: Cable